{"title":"Large Capacity Grease Traps","description":"\u003cp\u003eThe Drain-Net APGI Series Grease Interceptor is designed to separate grease, oils, fats, and other sediment from large Commercial and Industrial sources.\u003c\/p\u003e\n\u003cp\u003eMade of seamless High Density Polyethylene (HDPE), the APGI series interceptor is lightweight, cost efficient, extremely durable and corrosion free.\u003c\/p\u003e\n\u003cp\u003eNon skid 3\/4” poly covers with recessed handles are standard, but all units are available with steel non-skid tread plates for traffic areas.\u003c\/p\u003e\n\u003cp\u003eThe HDPE construction is acid resistant and solids do not easily adhere to the smooth walls, making cleaning effortless.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAbove or below ground installation\u003c\/li\u003e\n\u003cli\u003e1\/4\" Steel Cover for pedestrian traffic\u003c\/li\u003e\n\u003cli\u003eBolt on Extension\u003c\/li\u003e\n\u003cli\u003eRecessed Lift Handles.\u003c\/li\u003e\n\u003cli\u003eIntegral Extension on APGI-100\u003c\/li\u003e\n\u003cli\u003eOptional Connection Sizes 2, 3, 4, and 6 inches\u003c\/li\u003e\n\u003cli\u003ePVC glued connections are standard.\u003c\/li\u003e\n\u003cli\u003eHD Braces for above ground installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecial sizes available to fit through narrow passages or existing walkways. Special units also available to meet larger capacities, including systems that utilize series and\/or parallel interceptors.Straight through, left, and right hand models available.\u003c\/p\u003e\n\u003cp\u003eMost units ship in 5 to 7 business days. Click on product for more information.  \u003c\/p\u003e\n\u003cp\u003eNot sure what size Grease Interceptor you need?  \u003ca href=\"\/pages\/grease-trap-sizing-chart\"\u003eClick here to view the Grease Trap Sizing Formula\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;justify-content:center;align-items:center;margin-top:20px;\"\u003e\n\u003ca href=\"\/pages\/pdi\" style=\"display:block;max-width:178px;width:100%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pdi-web.jpg?v=1785882217\" alt=\"PDI certified grease interceptors\" style=\"display:block;width:100%;height:auto;\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/grease-trap-sizing-chart\" style=\"display:block;max-width:300px;width:100%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/what_size_grease_trap_do_i_need_-_2026_banner.jpg?v=1785882217\" alt=\"What size grease trap do I need?\" style=\"display:block;width:100%;height:auto;\"\u003e\u003c\/a\u003e\u003ca href=\"\/collections\/grease-trap-monitoring\" style=\"display:block;max-width:300px;width:100%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/grease_monitoring_system_banner2.jpg?v=1785882217\" alt=\"Grease monitoring system\" style=\"display:block;width:100%;height:auto;\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e","products":[{"product_id":"grease-interceptor-100-gpm-250-lbs","title":"Grease Trap 100 GPM - 250 LBS","description":"\u003cp\u003eThe Drain-Net Technologies' APGI Series Grease Interceptor is designed to separate grease, oils, fats, and other sediment from large Commercial and Industrial sources. Made of seamless High Density Polyethylene (HDPE), the APGI series interceptor is lightweight, cost efficient, extremely durable and corrosion free. Non skid 3\/4” poly covers with recessed handles are standard, but all units are available with steel non-skid tread plates for traffic areas. The HDPE construction is acid resistant and solids do not easily adhere to the smooth walls, making cleaning effortless.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAbove or below ground installation\u003c\/li\u003e \u003cli\u003e1\/4\" Steel Cover for pedestrian traffic\u003c\/li\u003e \u003cli\u003eBolt on Extension\u003c\/li\u003e \u003cli\u003eRecessed Lift Handles.\u003c\/li\u003e \u003cli\u003eIntegral Extension on APGI-100\u003c\/li\u003e \u003cli\u003eOptional Connection Sizes 2, 3, and 4 inches\u003c\/li\u003e \u003cli\u003ePVC glued connections are standard.\u003c\/li\u003e \u003cli\u003eHD Braces for above ground installation.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSpecial sizes available to fit through narrow passages or existing walkways. Special units also available to meet larger capacities, including systems that utilize series and\/or parallel interceptors. Straight through, left, and right hand models available. A lift-gate is highly recommended for delivery. All units made in the USA!\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecifications of Model DAPGI-100\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eFlow Rate: 100 GPM\u003c\/li\u003e \u003cli\u003eGrease \/ Sludge Capacity: 250 lbs\u003c\/li\u003e \u003cli\u003eApproximate Weight: 200 lbs\u003c\/li\u003e \u003cli\u003eStandard Inlet \/ Outlet: 3\"\u003c\/li\u003e \u003cli\u003eBottom of unit to center of inlet\/outlet: 24\"\u003c\/li\u003e \u003cli\u003eLiquid Holding Capacity: 112 gal\u003c\/li\u003e \u003cli\u003eDimensions: 52.5\" Length X 29\" Width X 32\" Height\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e*This size not recognized yet by PDI\/UPC\/IAMPMO\u003c\/p\u003e \u003cp\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-apgi-grease-trap-spec-sheet.pdf?v=1782492397\" target=\"_blank\"\u003e\u003cspan\u003e\u003cstrong\u003eClick to view and download the Spec Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e \u003ca href=\"\/collections\/wet-waste-interceptor\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/gdru-for-grease-trap-pages.jpg?v=1781750722\" alt=\"gdru-for-grease-trap-pages.jpg\" width=\"1988\" height=\"516\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/large_20capcity_20grease_20trap_20diagram4.jpg?v=1786834445\" alt=\"Large Capacity Grease Trap Grease Interceptor GPM Sizing Chart\"\u003e\u003c\/p\u003e","brand":"PolyTrap®","offers":[{"title":"Default Title","offer_id":52470383477047,"sku":"DAPGI-100","price":3450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Ashland_Large_Grease_Trap_2__94321.jpg?v=1781473860"},{"product_id":"endura-xl-grease-interceptor-75-gpm","title":"Hydromechanical 75 GPM XL Grease Interceptor","description":"\u003ch4\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/engineered_for_easy__87083.1433970012.1280.1280.jpg?v=1781750716\" alt=\"grease interceptor for restaurants\" width=\"500\" height=\"416\"\u003e\u003c\/span\u003e\u003c\/h4\u003e \u003ch4\u003e\u003cspan\u003eFlow Management\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003eThe Endura XL is a Hydromechanical Grease Interceptor (HGI). Unlike traditional, large capacity Gravity Grease Interceptors (GGI), our design uses more than just the natural buoyancy of fats, oils and grease (FOG) to separate them from waste water. This results in qualified efficiency based on National performance standards to ensure the most effective removal of grease.\u003c\/p\u003e \u003ch4\u003e\u003cspan\u003eSolids Retention Area\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003ePassing over the ramp, any solids or debris separate by gravity into the defined solids retention area. This significantly reduces the likelihood of grease laden particles from exiting the interceptor.\u003c\/p\u003e \u003ch4\u003e\u003cspan\u003eOutlet Well Features\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003eWith FOG and solids having been effectively separated, the waste water leaves the tank via our uniquely enclosed outlet well, the effluent being discharged to the downstream drain through one of three pre-plumbed tank outlets.\u003c\/p\u003e \u003ch3\u003e\u003cspan\u003eHighlights:\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/grease_trap_engineer__79169.1433880237.1280.1280.jpg?v=1781750716\" alt=\"Grease Interceptor XL Diagram\" width=\"375\" height=\"309\"\u003e559 LB Capacity and 98% Efficiency\u003c\/li\u003e \u003cli\u003eDynamic Inlet Baffle - Internal flow Control (Supplied Standard)\u003c\/li\u003e \u003cli\u003eOptional External flow control (PDIG101)\u003c\/li\u003e \u003cli\u003eSeamless Tank - Rotationally molded using up to 100% re-compounded material\u003c\/li\u003e \u003cli\u003eDual Access Covers - Traffic Rated (CSA B481.1 Type 'S') Rated in excess of 20,000lb\u003c\/li\u003e \u003cli\u003eAirtight\/Watertight cover, frame and adjustable riser system\u003c\/li\u003e \u003cli\u003e\n\u003ca title='18\" Grease Trap Riser' href=\"\/products\/extension-riser-pair-18-inch-for-endura-xl-grease-interceptor\"\u003e18\" Riser\u003c\/a\u003e and \u003ca title='35\" Grease Trap Riser Extension' href=\"\/products\/extension-riser-pair-35-inch-for-endura-xl-grease-interceptor\"\u003e35\" Riser\u003c\/a\u003e Extensions available\u003c\/li\u003e \u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eSpecs\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eFlow Rate (GPM): 75\u003c\/li\u003e \u003cli\u003eFlow Rate (L\/Sec): 4.74\u003c\/li\u003e \u003cli\u003eCapacity: Lbs (MIN) 150 \/ Kg (MIN) 91\u003c\/li\u003e \u003cli\u003eCapacity (Actual - ASME A112.4.3): 559 Lbs \/ 253 Kg\u003c\/li\u003e \u003cli\u003eSolids Capacity Lbs (Kg) estimated: 260lbs (118kg) 45 Gallons\u003c\/li\u003e \u003cli\u003eAverage Efficiency % (ASME A112.4.3): 98%\u003c\/li\u003e \u003cli\u003eOperating Temperature Capabilities (Intermittent discharge): 160° F (71°C)\u003c\/li\u003e \u003cli\u003eUnit Weight Capacity (Empty): 233 lbs (106 kgs)\u003c\/li\u003e \u003cli\u003eLiquid Capacity: 158 gal (598L)\u003c\/li\u003e \u003cli\u003eConnection size (mechanical): 4\"\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/pages\/cad-drawings\"\u003eView and download CAD Drawings and Submittal Sheets\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003cstrong\u003ePlease note that this product ships via LTL, only to commercial locations. Please contact us with questions. We only ship this to lower 48 states. \u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eCover Options\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cspan\u003eHeavy Traffic Area Covers\u003c\/span\u003e - S-Rated Traffic Access Covers (up to 20,000 lbs)\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003ePedestrian \/ Light Traffic Covers\u003c\/span\u003e - M-Rated Traffic Access Covers \u003cspan\u003e(up to 4,000 lbs)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eCast Iron Access Covers\u003c\/span\u003e - with 2 pry points and pick hole for easy removal. (Only available with hub connection model)\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/XL_75gpm_specs__31101.1433882081.1280.1280.jpg?v=1781750716\" alt=\"XL Grease Interceptor 75 GPM Specs\" width=\"800\" height=\"473\"\u003e \u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/hcgi-cert.jpg?v=1781750723\" alt=\"Grease trap certifications\" width=\"394\" height=\"101\"\u003e \u003c\/p\u003e \u003ch3\u003eBrochures and Spec Sheets\u003c\/h3\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-xl-grease-interceptor-brochure.pdf?v=1782492392\" target=\"_blank\"\u003eDrain-Net XL Grease Interceptor Brochure\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/grease-interceptor-xl-spec-sheet.pdf?v=1782492409\" target=\"_blank\"\u003eDrain-Net XL 75 GPM Grease Interceptor Spec Sheet\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"\/pages\/cad-drawings\"\u003eView and download CAD Drawings and Submittal Sheets\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-hgi-comparison-matrix.pdf?v=1782492394\" target=\"_blank\"\u003eDrain-Net Comparison Sheet to other brands\u003c\/a\u003e\u003c\/p\u003e \u003ch3\u003eFrequently Asked Questions:\u003c\/h3\u003e \u003cp\u003e\u003cstrong\u003eDo Drain-Net XL Tanks need to be directly vented?\u003c\/strong\u003e\u003cbr\u003eThe practice of venting a grease interceptor directly is typically related to Gravity Grease Interceptors (GGI). Unless specifically mandated by local code or bylaw, with no variance allowed, a Hydromechanical Grease Interceptor (HGI) DOES NOT require the tank to be directly vented. Venting is, however, required on the downstream drain the same as most plumbing appliances; fixtures should allow effective and unrestricted discharge of effluent.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDo I need to install a clean out before or after an interceptor?\u003c\/strong\u003e\u003cbr\u003eMost plumbing codes require an upstream and downstream cleanout immediately before and after the interceptor. This is good practice and gives positive indication of which outlet is in use.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDo I have to install the Flow Control Device?\u003c\/strong\u003e\u003cbr\u003eFor an HGI, the Flow Control is ESSENTIAL to the high performance operation of the interceptor. It must be installed as indicated and without it the interceptor is no longer meeting the requirements of its appropriate approvals. This is not acceptable to the AHJ and they should be asking for the installation to be rectified before approval is granted.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow do I size a Grease Interceptor correctly?\u003c\/strong\u003e\u003cbr\u003eA grease Interceptor can be sized using two primary methods\u003cbr\u003e1. Flow Rate – When sizing by Flow Rate there are two sub sections \u003cbr\u003eFixture Capacity: Most commonly used method for Hydromechanical Grease Interceptors this looks at the maximum capacity of fixtures connected to the interceptor and the time taken to discharge that volume of wastewater through the interceptor. Units are expressed in Gallons Per Minute (GPM). \u003cbr\u003eCalculation takes 75% of maximum capacity of all fixtures and based on a 1 or 2 minute period of time taken to discharge, results in a gallons per minute flow rate. This number is rounded up to the next available size of interceptor, i.e. 16.7gpm become a 20 GPM Grease Interceptor.\u003c\/p\u003e \u003cp\u003e1. Pipe Size:\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pipe-size.png?v=1781750727\" alt=\"pipe-size.png\" width=\"631\" height=\"181\"\u003e\u003c\/p\u003e \u003cp\u003e2. Capacity\u003c\/p\u003e \u003cp\u003eBased on the volume of wastewater capacity (gallons) of the interceptor based on discharge fixture units (DFU’s) entering the interceptor\u003cbr\u003eDFU’s are identified in Uniform Plumbing Code Ch.7 based on occupancy or use.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/capacity.png?v=1781750725\" alt=\"capacity.png\" width=\"687\" height=\"171\"\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMy jurisdiction requires Effluent Sampling via a downstream access. What do I do?\u003c\/strong\u003e \u003cbr\u003eAs an HGI approved to National performance Standards, although common for GGI (Concrete, Steel) Drain-Net XL DOES NOT typically require a separate sampling location. For those jurisdictions that do require the capability to sample, Drain-Net XL incorporates a sampling port within the \u003ca href=\"\/products\/xl-sampling-well\"\u003eoutlet assembly (sold here)\u003c\/a\u003e. This is accessed by the simple removal of the air balance\/sample port cap allowing water quality samples to be taken for analysis.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow often should an interceptor be cleaned?\u003c\/strong\u003e\u003cbr\u003eCleaning of an interceptor is a case by case situation. Each facility will have many different factors impacting need for maintenance and cleaning. A licensed contractor will have the experience and equipment necessary to help establish the right schedule of maintenance for your facility. How much will it cost to maintain my Drain-Net XL installation?\u003cbr\u003eIn terms of comparison Drain-Net XL units are significantly more compact (less internal volume) than their equivalent Gravity counterparts. As pumping is typically charged by the volume of gallons removed the ongoing maintenance will be proportionally less as well. Rates will vary significantly by region and by contractor. Always use a licensed or approved contractor to maintain your interceptor.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWhat can be connected to an interceptor in respect of wastewater discharge?\u003c\/strong\u003e\u003cbr\u003eA grease interceptor UNDER NO CIRCUMSTANCES will receive sanitary wastewater discharge – i.e. that from WC flushing for example. \u003cbr\u003eWastewater discharge to a grease interceptor will be from foodservice activities only, its application being to separate non petroleum Fats Oil and Grease from waste water. \u003cbr\u003eThe requirements for appliances and fixtures that must and must not be connected to a grease interceptor is typically defined by your local plumbing codes and or jurisdictional by-laws. You should consult a licensed plumbing professional or your local city plan check.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow does a compact HGI replace the function of a 1000 gallon concrete tank?\u003c\/strong\u003e\u003cbr\u003eA Gravity Grease Interceptor (your typical concrete tank) will be sized on capacity and therefore typically a number between 750gallons and 1500gallons is commonly seen. This number can however be substantially higher based on local requirement or application. In most jurisdictions, a method called the 25% rule is employed as the means to indicate or mandate the cleaning frequency. The 25% is the percentage of the total working volume of the interceptor which can be occupied by a combination of Fats , Oil and Grease and Food Solids. \u003cbr\u003eFor example: A GGI tank with a capacity of 1000 gallons can only function to a point where 250gallons (1000 X .25) of its volume is occupied by solids and grease. That equates to approximately 1090 LBS of grease. If we assumed that 100 gallons of this is the solid material, that leaves 150 gallons of grease capacity before cleaning is “required”. On average this translates to approximately 8-10 weeks on average. \u003cbr\u003eNow compare that to an XL100 HGI. Based on the independent third party testing to determine qualified performance \u0026amp; efficiency, the Drain-Net XL100 has a significantly smaller 257gallon total capacity, but a qualified efficiency exceeding 95%. This translates to essentially the same grease capacity as the GGI, exceeding 1000lbs of functional grease capacity.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eI heard that plastic tanks can float in high water table areas, particularly when pumped down for cleaning.\u003c\/strong\u003e \u003cbr\u003eIs this true? \u003cbr\u003eYes it is, however Drain-Net XL is specifically designed to address this challenge. If you look at XL tanks from the end you will see that the top is wider than the bottom and that there are along the sides corrugations that are closed toward the bottom of their profile. This profile is the reverse of an ice cube sitting in a freezer tray. Typically some upward force is applied around or beneath the ice cube and out it pops! Now reverse that principle to the form of the tanks – the broad base not only provides stability but also has substantial resistance to being force upward by water or freeze-thaw action. This in conjunction with the closed corrugations positively captures the tank in the excavation once backfilled. For areas of particular concern in addition an 8” concrete slab can be poured around the base to introduce further resistance. Provision is also made for the use of ground anchors or alternates that will need to be specified locally by an engineer respective of local ground conditions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCan I install more than one Drain-Net XL unit if my jurisdiction needs a minimum capacity by code?\u003c\/strong\u003e \u003cbr\u003eIn Principal, yes you can. It will be necessary you contact your plan check or review team at the authority having jurisdiction and have your engineer submit a proposal based on the information provided.\u003c\/p\u003e \u003ch3\u003eUseful Terms and Definitions\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHGI\u003c\/strong\u003e – Industry abbreviation for Hydromechanical Grease Interceptor. By definition an HGI is designed to use managed flow, air entrainment and specifically designed features to provide an enhanced level of separation efficiency, removing non petroleum FOG (Fats, Oil and Grease) from a transition flow of waste water, generated by commercial foodservice activities (Restaurants, Cafeterias, Institutional Kitchens , Sandwich Shops and Coffee houses for example). HGI’s are performance tested for efficiency of grease separation based on National Standards. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index =1\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGGI\u003c\/strong\u003e - Industry abbreviation for Gravity Grease Interceptor. By definition a GGI has a minimum of 350USG capacity and in operation 500USG to 1500USG of capacity are most common. No flow control device. Separation of FOG is based on capacity and retention time of water (minimum 30 mins to exchange volume). At this time no performance Standards are published for GGI’s. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index = 5-10+\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGRD\u003c\/strong\u003e – Industry abbreviation for Grease Removal Device. Designed firstly as an HGI, a GRD uses a heat source and a timed or sensor based skimming (or draw-off) device to remove accumulated FOG from the separation chamber into an external container for collection and disposal. These units require daily maintenance for management of food solids. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index = 2.5 - 5\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCost Index\u003c\/strong\u003e: A way of indicating the relative cost of different types of interceptors to each other for broad comparison purposes. This includes product purchase, installation cost and typical maintenance.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAir Entrainment\u003c\/strong\u003e: Mixing of air with Influent using a flow control device. Air and grease are attracted to each other, the air wanting to separate from water more easily than grease. Because they become mixed together the air increases the efficiency of separation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEffluent\u003c\/strong\u003e: Waste water containing little to no FOG, being discharged out of the interceptor.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInfluent\u003c\/strong\u003e: Waste water containing uncontrolled and variable levels of FOG based on the nature and practices of the foodservice operation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSeparation Chamber\u003c\/strong\u003e: Zone inside the interceptor where grease separates from water and is retained.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003ca href=\"\/collections\/wet-waste-interceptor\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/gdru-for-grease-trap-pages_55906dd1-ce2e-4a4a-9cc2-f4eab9457f6b.jpg?v=1781750726\" alt=\"gdru-for-grease-trap-pages.jpg\" width=\"1988\" height=\"516\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/engineered_for_easy.jpg?v=1786831645\" alt=\"FOG and solids\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Pre-Plumbed_Options.jpg?v=1786831609\" alt=\"outlet options for the grease trap\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/dynamic_inlet.jpg?v=1786831639\" alt=\"dynamic inclet baffle\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/flow_control.jpg?v=1786831651\" alt=\"Integrated flow control for grease interceptor\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/load_rated_covers.gif?v=1786831655\" alt=\"load rated covers for grease interceptor endura xl\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/effluent_sampling.png?v=1786831642\" alt=\"Integrated Water Effluent Sampling\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/riser_extensions.jpg?v=1786831677\" alt=\"under ground grease interceptor riser extension\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/smart_tank_design.jpg?v=1786831683\" alt=\"grease interceptor xl design\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/HGI-75gpm-specs.jpg?v=1786831606\" alt=\"75 GPM Grease Trap\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pickup_locations_5beef30d-8e05-4207-85fc-94fd88852f20.jpg?v=1786834699\" alt=\"pickup locations\"\u003e\u003c\/p\u003e","brand":"Endura XL Grease Traps","offers":[{"title":"Traffic Rated Cover - CSA B481.0 'S' Rated","offer_id":52470387278135,"sku":"HGI-75-04","price":2716.0,"currency_code":"USD","in_stock":true},{"title":"Pedestrian \/ Light Traffic Covers - CSA B481.0 'M' Rated","offer_id":52470387310903,"sku":"HGI-75-04M","price":2500.0,"currency_code":"USD","in_stock":true},{"title":"Cast Iron Access Covers","offer_id":52470387343671,"sku":"HGI-75-04C","price":2716.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Endura_XL_Grease_Interceptor_75_GPM__08802.jpg?v=1781474004"},{"product_id":"endura-xl-grease-interceptor-100-gpm","title":"Hydromechanical 100 GPM XL Grease Interceptor","description":"\u003ch4\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/engineered_for_easy__87083.1433970012.1280.1280.jpg?v=1781750716\" alt=\"grease interceptor for restaurants\" width=\"500\" height=\"416\"\u003eFlow Management\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003eEndura XL is a Hydromechanical Grease Interceptor (HGI). Unlike traditional, large capacity Gravity Grease Interceptors (GGI), our design uses more than just the natural buoyancy of fats, oils and grease (FOG) to separate them from waste water. This results in qualified efficiency based on National performance standards to ensure the most effective removal of grease.\u003c\/p\u003e \u003ch4\u003e\u003cspan\u003eSolids Retention Area\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003ePassing over the ramp, any solids or debris separate by gravity into the defined solids retention area. This significantly reduces the likelihood of grease laden particles from exiting the interceptor.\u003c\/p\u003e \u003ch4\u003e\u003cspan\u003eOutlet Well Features\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003eWith FOG and solids having been effectively separated, the waste water leaves the tank via our uniquely enclosed outlet well, the effluent being discharged to the downstream drain through one of three pre-plumbed tank outlets.\u003c\/p\u003e \u003ch3\u003e\u003cspan\u003eHighlights:\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/grease_trap_engineer__79169.1433880237.1280.1280.jpg?v=1781750716\" alt=\"Grease Interceptor XL Diagram\" width=\"375\" height=\"309\"\u003e1058 LB Capacity and 98% Efficiency\u003c\/li\u003e \u003cli\u003eDynamic Inlet Baffle - Internal flow Control (Supplied Standard)\u003c\/li\u003e \u003cli\u003eOptional External flow control (PDIG101)\u003c\/li\u003e \u003cli\u003eSeamless Tank - Rotationally molded using up to 100% re-compounded material\u003c\/li\u003e \u003cli\u003eDual Access Covers - Traffic Rated (CSA B481.1 Type 'S') Rated in excess of 20,000lb\u003c\/li\u003e \u003cli\u003eAirtight\/Watertight cover, frame and adjustable riser system\u003c\/li\u003e \u003cli\u003e\n\u003ca title='18\" Grease Trap Riser' href=\"\/products\/extension-riser-pair-18-inch-for-endura-xl-grease-interceptor\"\u003e18\" Riser\u003c\/a\u003e and \u003ca title='35\" Grease Trap Riser Extension' href=\"\/products\/extension-riser-pair-35-inch-for-endura-xl-grease-interceptor\"\u003e35\" Riser\u003c\/a\u003e Extensions available\u003c\/li\u003e \u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e \u003cli\u003e\u003cstrong\u003ePlease note that this product ships via LTL, only to commercial locations. Please contact us with questions. We only ship this to lower 48 states. \u003c\/strong\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eSpecs\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eFlow Rate (GPM): 100\u003c\/li\u003e \u003cli\u003eFlow Rate (L\/Sec): 6.31\u003c\/li\u003e \u003cli\u003eCapacity: Lbs (MIN) 200 \/ Kg (MIN) 91\u003c\/li\u003e \u003cli\u003eCapacity (Actual - ASME A112.4.3): 1080 Lbs \/ 480 Kg\u003c\/li\u003e \u003cli\u003eSolids Capacity Lbs (Kg) estimated: 350lbs (118kg) 60 Gallons\u003c\/li\u003e \u003cli\u003eAverage Efficiency % (ASME A112.4.3): 99%\u003c\/li\u003e \u003cli\u003eOperating Temperature Capabilities (Intermittent discharge): 160° F (71°C)\u003c\/li\u003e \u003cli\u003eUnit Weight Capacity (Empty): 283 lbs (128 kgs)\u003c\/li\u003e \u003cli\u003eLiquid Capacity: 257 gal (973L)\u003c\/li\u003e \u003cli\u003eConnection size (mechanical): 4\"\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/pages\/cad-drawings\"\u003eView and download CAD Drawings and Submittal Sheets\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eCover Options\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHeavy Traffic Area Covers\u003c\/strong\u003e - S-Rated Traffic Access Covers (up to 20,000 LBS)\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePedestrian \/ Light Traffic Covers\u003c\/strong\u003e - M-Rated Traffic Access Covers \u003cspan\u003e(up to 4,000 LBS)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003eCast Iron Access Covers\u003c\/strong\u003e - with 2 pry points and pick hole for easy removal. (Only available with hub connection model)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/XL_100GPM_specs__73826.1433970967.1280.1280.jpg?v=1781750716\" alt=\"XL Grease Interceptor 100 GPM Specs\" width=\"800\" height=\"433\"\u003e \u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/hcgi-cert.jpg?v=1781750723\" alt=\"Grease trap certifications\" width=\"394\" height=\"101\"\u003e \u003c\/p\u003e \u003ch3\u003eBrochures and Spec Sheets\u003c\/h3\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-xl-grease-interceptor-brochure.pdf?v=1782492392\" target=\"_blank\"\u003eDrain-Net XL Grease Interceptor Brochure\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/grease-interceptor-xl-100gpm-spec-sheet.pdf?v=1782492408\" target=\"_blank\"\u003eDrain-Net XL 100 GPM Grease Interceptor Spec Sheet\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"\/pages\/cad-drawings\"\u003eView and download CAD Drawings and Submittal Sheets\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-hgi-comparison-matrix.pdf?v=1782492394\" target=\"_blank\"\u003eDrain-Net Comparison Sheet to other brands\u003c\/a\u003e\u003c\/p\u003e \u003ch3\u003eFrequently Asked Questions:\u003c\/h3\u003e \u003cp\u003e\u003cstrong\u003eDo Drain-Net XL Tanks need to be directly vented?\u003c\/strong\u003e\u003cbr\u003eThe practice of venting a grease interceptor directly is typically related to Gravity Grease Interceptors (GGI). Unless specifically mandated by local code or bylaw, with no variance allowed, a Hydromechanical Grease Interceptor (HGI) DOES NOT require the tank to be directly vented. Venting is, however, required on the downstream drain the same as most plumbing appliances; fixtures should allow effective and unrestricted discharge of effluent.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDo I need to install a clean out before or after an interceptor?\u003c\/strong\u003e\u003cbr\u003eMost plumbing codes require an upstream and downstream cleanout immediately before and after the interceptor. This is good practice and gives positive indication of which outlet is in use.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDo I have to install the Flow Control Device?\u003c\/strong\u003e\u003cbr\u003eFor an HGI, the Flow Control is ESSENTIAL to the high performance operation of the interceptor. It must be installed as indicated and without it the interceptor is no longer meeting the requirements of its appropriate approvals. This is not acceptable to the AHJ and they should be asking for the installation to be rectified before approval is granted.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow do I size a Grease Interceptor correctly?\u003c\/strong\u003e\u003cbr\u003eA grease Interceptor can be sized using two primary methods\u003cbr\u003e1. Flow Rate – When sizing by Flow Rate there are two sub sections \u003cbr\u003eFixture Capacity: Most commonly used method for Hydromechanical Grease Interceptors this looks at the maximum capacity of fixtures connected to the interceptor and the time taken to discharge that volume of wastewater through the interceptor. Units are expressed in Gallons Per Minute (GPM). \u003cbr\u003eCalculation takes 75% of maximum capacity of all fixtures and based on a 1 or 2 minute period of time taken to discharge, results in a gallons per minute flow rate. This number is rounded up to the next available size of interceptor, i.e. 16.7gpm become a 20 GPM Grease Interceptor.\u003c\/p\u003e \u003cp\u003e1. Pipe Size:\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pipe-size.png?v=1781750727\" alt=\"pipe-size.png\" width=\"631\" height=\"181\"\u003e\u003c\/p\u003e \u003cp\u003e2. Capacity\u003c\/p\u003e \u003cp\u003eBased on the volume of wastewater capacity (gallons) of the interceptor based on discharge fixture units (DFU’s) entering the interceptor\u003cbr\u003eDFU’s are identified in Uniform Plumbing Code Ch.7 based on occupancy or use.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/capacity.png?v=1781750725\" alt=\"capacity.png\" width=\"687\" height=\"171\"\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMy jurisdiction requires Effluent Sampling via a downstream access. What do I do?\u003c\/strong\u003e\u003cbr\u003eAs an HGI approved to National performance Standards, although common for GGI (Concrete, Steel) Drain-Net XL DOES NOT typically require a separate sampling location. For those jurisdictions that do require the capability to sample, Drain-Net XL incorporates a sampling port within the \u003ca href=\"\/products\/xl-sampling-well\"\u003eoutlet assembly (sold here)\u003c\/a\u003e. This is accessed by the simple removal of the air balance\/sample port cap allowing water quality samples to be taken for analysis.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow often should an interceptor be cleaned?\u003c\/strong\u003e\u003cbr\u003eCleaning of an interceptor is a case by case situation. Each facility will have many different factors impacting need for maintenance and cleaning. A licensed contractor will have the experience and equipment necessary to help establish the right schedule of maintenance for your facility. How much will it cost to maintain my Drain-Net XL installation?\u003cbr\u003eIn terms of comparison Drain-Net XL units are significantly more compact (less internal volume) than their equivalent Gravity counterparts. As pumping is typically charged by the volume of gallons removed the ongoing maintenance will be proportionally less as well. Rates will vary significantly by region and by contractor. Always use a licensed or approved contractor to maintain your interceptor.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWhat can be connected to an interceptor in respect of wastewater discharge?\u003c\/strong\u003e\u003cbr\u003eA grease interceptor UNDER NO CIRCUMSTANCES will receive sanitary wastewater discharge – i.e. that from WC flushing for example. \u003cbr\u003eWastewater discharge to a grease interceptor will be from foodservice activities only, its application being to separate non petroleum Fats Oil and Grease from waste water. \u003cbr\u003eThe requirements for appliances and fixtures that must and must not be connected to a grease interceptor is typically defined by your local plumbing codes and or jurisdictional by-laws. You should consult a licensed plumbing professional or your local city plan check.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow does a compact HGI replace the function of a 1000 gallon concrete tank?\u003c\/strong\u003e\u003cbr\u003eA Gravity Grease Interceptor (your typical concrete tank) will be sized on capacity and therefore typically a number between 750 gallons and 1500 gallons is commonly seen. This number can however be substantially higher based on local requirement or application. In most jurisdictions, a method called the 25% rule is employed as the means to indicate or mandate the cleaning frequency. The 25% is the percentage of the total working volume of the interceptor which can be occupied by a combination of Fats , Oil and Grease and Food Solids. \u003cbr\u003eFor example: A GGI tank with a capacity of 1000 gallons can only function to a point where 250 gallons (1000 X .25) of its volume is occupied by solids and grease. That equates to approximately 1090 lbs of grease. If we assumed that 100 gallons of this is the solid material, that leaves 150 gallons of grease capacity before cleaning is “required”. On average this translates to approximately 8-10 weeks on average. \u003cbr\u003eNow compare that to an XL100 HGI. Based on the independent third party testing to determine qualified performance \u0026amp; efficiency, the Drain-Net XL100 has a significantly smaller 257 gallon total capacity, but a qualified efficiency exceeding 95%. This translates to essentially the same grease capacity as the GGI, exceeding 1000 lbs of functional grease capacity.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eI heard that plastic tanks can float in high water table areas, particularly when pumped down for cleaning.\u003c\/strong\u003e \u003cbr\u003eIs this true? \u003cbr\u003eYes it is, however Drain-Net XL is specifically designed to address this challenge. If you look at XL tanks from the end you will see that the top is wider than the bottom and that there are along the sides corrugations that are closed toward the bottom of their profile. This profile is the reverse of an ice cube sitting in a freezer tray. Typically some upward force is applied around or beneath the ice cube and out it pops! Now reverse that principle to the form of the tanks – the broad base not only provides stability but also has substantial resistance to being force upward by water or freeze-thaw action. This in conjunction with the closed corrugations positively captures the tank in the excavation once backfilled. For areas of particular concern in addition an 8” concrete slab can be poured around the base to introduce further resistance. Provision is also made for the use of ground anchors or alternates that will need to be specified locally by an engineer respective of local ground conditions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCan I install more than one Drain-Net XL unit if my jurisdiction needs a minimum capacity by code?\u003c\/strong\u003e \u003cbr\u003eIn Principal, yes you can. It will be necessary you contact your plan check or review team at the authority having jurisdiction and have your engineer submit a proposal based on the information provided.\u003c\/p\u003e \u003ch3\u003eUseful Terms and Definitions\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHGI\u003c\/strong\u003e – Industry abbreviation for Hydromechanical Grease Interceptor. By definition an HGI is designed to use managed flow, air entrainment and specifically designed features to provide an enhanced level of separation efficiency, removing non petroleum FOG (Fats, Oil and Grease) from a transition flow of waste water, generated by commercial foodservice activities (Restaurants, Cafeterias, Institutional Kitchens , Sandwich Shops and Coffee houses for example). HGI’s are performance tested for efficiency of grease separation based on National Standards. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index =1\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGGI\u003c\/strong\u003e - Industry abbreviation for Gravity Grease Interceptor. By definition a GGI has a minimum of 350USG capacity and in operation 500USG to 1500USG of capacity are most common. No flow control device. Separation of FOG is based on capacity and retention time of water (minimum 30 mins to exchange volume). At this time no performance Standards are published for GGI’s. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index = 5-10+\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGRD\u003c\/strong\u003e – Industry abbreviation for Grease Removal Device. Designed firstly as an HGI, a GRD uses a heat source and a timed or sensor based skimming (or draw-off) device to remove accumulated FOG from the separation chamber into an external container for collection and disposal. These units require daily maintenance for management of food solids. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index = 2.5 - 5\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCost Index\u003c\/strong\u003e: A way of indicating the relative cost of different types of interceptors to each other for broad comparison purposes. This includes product purchase, installation cost and typical maintenance.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAir Entrainment\u003c\/strong\u003e: Mixing of air with Influent using a flow control device. Air and grease are attracted to each other, the air wanting to separate from water more easily than grease. Because they become mixed together the air increases the efficiency of separation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEffluent\u003c\/strong\u003e: Waste water containing little to no FOG, being discharged out of the interceptor.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInfluent\u003c\/strong\u003e: Waste water containing uncontrolled and variable levels of FOG based on the nature and practices of the foodservice operation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSeparation Chamber\u003c\/strong\u003e: Zone inside the interceptor where grease separates from water and is retained.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003ca href=\"\/collections\/wet-waste-interceptor\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/gdru-for-grease-trap-pages_55906dd1-ce2e-4a4a-9cc2-f4eab9457f6b.jpg?v=1781750726\" alt=\"gdru-for-grease-trap-pages.jpg\" width=\"1988\" height=\"516\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/engineered_for_easy.jpg?v=1786831645\" alt=\"Buried grease interceptor\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Pre-Plumbed_Options.jpg?v=1786831609\" alt=\"outlet options for the grease trap\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/dynamic_inlet.jpg?v=1786831639\" alt=\"dynamic inclet baffle\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/flow_control.jpg?v=1786831651\" alt=\"Integrated flow control for grease interceptor\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/load_rated_covers.gif?v=1786831655\" alt=\"load rated covers for grease interceptor endura xl\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/effluent_sampling.png?v=1786831642\" alt=\"Integrated Water Effluent Sampling\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/riser_extensions.jpg?v=1786831677\" alt=\"under ground grease interceptor riser extension\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/smart_tank_design.jpg?v=1786831683\" alt=\"grease interceptor xl design\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/100GPM-specs.jpg?v=1786831658\" alt=\"100GPM specs\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pickup_locations_5beef30d-8e05-4207-85fc-94fd88852f20.jpg?v=1786834699\" alt=\"pickup locations\"\u003e\u003c\/p\u003e","brand":"Endura XL Grease Traps","offers":[{"title":"Traffic Rated Cover - CSA B481.0 'S' Rated","offer_id":52470387409207,"sku":"HGI-100-04","price":4798.0,"currency_code":"USD","in_stock":true},{"title":"Pedestrian \/ Light Traffic Covers - CSA B481.0 'M' Rated","offer_id":52470387441975,"sku":"HGI-100-04M","price":4763.0,"currency_code":"USD","in_stock":true},{"title":"Cast Iron Access Covers","offer_id":52470387474743,"sku":"HGI-100-04C","price":4798.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Large_Capacity_Grease_Trap_XL_150__68397.jpg?v=1781474006"},{"product_id":"grease-interceptor-225-gpm-500-lbs","title":"Grease Trap 225 GPM - 500 LBS","description":"\u003cp\u003eThe Drain-Net Technologies APGI Series Grease Interceptor is designed to separate grease, oils, fats, and other sediment from large Commercial and Industrial sources. Made of seamless High Density Polyethylene (HDPE), the APGI series interceptor is lightweight, cost efficient, extremely durable and corrosion free. Non skid 3\/4” poly covers with recessed handles are standard, but all units are available with steel non-skid tread plates for traffic areas. The HDPE construction is acid resistant and solids do not easily adhere to the smooth walls, making cleaning effortless.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAbove or below ground installation\u003c\/li\u003e \u003cli\u003e1\/4\" Steel Cover for pedestrian traffic\u003c\/li\u003e \u003cli\u003eBolt on Extension\u003c\/li\u003e \u003cli\u003eRecessed Lift Handles.\u003c\/li\u003e \u003cli\u003eStandard connection size: 4\" and optional Connection Sizes 2, 3, and 6 inches\u003c\/li\u003e \u003cli\u003ePVC glued connections are standard.\u003c\/li\u003e \u003cli\u003eHD Braces for above ground installation.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSpecial sizes available to fit through narrow passages or existing walkways. Special units also available to meet larger capacities, including systems that utilize series and\/or parallel interceptors. Straight through, left, and right hand models available. A lift-gate is highly recommended for delivery. All units made in the USA!\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecifications of Model DAPGI-225\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eFlow Rate: 225 GPM\u003c\/li\u003e \u003cli\u003eGrease \/ Sludge Capacity: 500 lbs\u003c\/li\u003e \u003cli\u003eApproximate Weight: 425 lbs\u003c\/li\u003e \u003cli\u003eStandard Inlet \/ Outlet: 4\"\u003c\/li\u003e \u003cli\u003eBottom of unit to center of inlet\/outlet: 45\"\u003c\/li\u003e \u003cli\u003eLiquid Holding Capacity: 300 gal\u003c\/li\u003e \u003cli\u003eDimensions: 53\" Length X 41\" Width X 49.5\" Height \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e*This size not recognized yet by PDI\/UPC\/IAMPMO\u003c\/p\u003e \u003cp\u003e\u003cspan\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-apgi-grease-trap-spec-sheet.pdf?v=1782492397\" target=\"_blank\"\u003e\u003cspan\u003e\u003cstrong\u003eClick to view and download the Spec Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"\/collections\/wet-waste-interceptor\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/gdru-for-grease-trap-pages.jpg?v=1781750722\" alt=\"gdru-for-grease-trap-pages.jpg\" width=\"1988\" height=\"516\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/large_20capcity_20grease_20trap_20diagram4.jpg?v=1786834445\" alt=\"Large Capacity Grease Trap Grease Interceptor GPM Sizing Chart\"\u003e\u003c\/p\u003e","brand":"PolyTrap®","offers":[{"title":"Default Title","offer_id":52470388261175,"sku":"DAPGI-225","price":7100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Ashland_Large_Grease_Trap_2__57702.jpg?v=1781474023"},{"product_id":"endura-xl-grease-interceptor-150-gpm","title":"Hydromechanical 150 GPM XL Grease Interceptor","description":"\u003ch4\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/engineered_for_easy__87083.1433970012.1280.1280.jpg?v=1781750716\" alt=\"grease interceptor for restaurants\" width=\"500\" height=\"416\"\u003eFlow Management\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003eEndura XL is a Hydromechanical Grease Interceptor (HGI). Unlike traditional, large capacity Gravity Grease Interceptors (GGI), our design uses more than just the natural buoyancy of fats, oils and grease (FOG) to separate them from waste water. This results in qualified efficiency based on National performance standards to ensure the most effective removal of grease.\u003c\/p\u003e \u003ch4\u003e\u003cspan\u003eSolids Retention Area\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003ePassing over the ramp, any solids or debris separate by gravity into the defined solids retention area. This significantly reduces the likelihood of grease laden particles from exiting the interceptor.\u003c\/p\u003e \u003ch4\u003e\u003cspan\u003eOutlet Well Features\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003eWith FOG and solids having been effectively separated, the waste water leaves the tank via our uniquely enclosed outlet well, the effluent being discharged to the downstream drain through one of three pre-plumbed tank outlets.\u003c\/p\u003e \u003ch3\u003e\u003cspan\u003eHighlights:\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/grease_trap_engineer__79169.1433880237.1280.1280.jpg?v=1781750716\" alt=\"Grease Interceptor XL Diagram\" width=\"375\" height=\"309\"\u003e1058 LB Capacity and 98% Efficiency\u003c\/li\u003e \u003cli\u003eDynamic Inlet Baffle - Internal flow Control (Supplied Standard)\u003c\/li\u003e \u003cli\u003eOptional External flow control (PDIG101)\u003c\/li\u003e \u003cli\u003eSeamless Tank - Rotationally molded using up to 100% re-compounded material\u003c\/li\u003e \u003cli\u003eDual Access Covers - Traffic Rated (CSA B481.1 Type 'S') Rated in excess of 20,000lb\u003c\/li\u003e \u003cli\u003eAirtight\/Watertight cover, frame and adjustable riser system\u003c\/li\u003e \u003cli\u003e\n\u003ca title='18\" Grease Trap Riser' href=\"\/products\/extension-riser-pair-18-inch-for-endura-xl-grease-interceptor\"\u003e18\" Riser\u003c\/a\u003e and \u003ca title='35\" Grease Trap Riser Extension' href=\"\/products\/extension-riser-pair-35-inch-for-endura-xl-grease-interceptor\"\u003e35\" Riser\u003c\/a\u003e Extensions available\u003c\/li\u003e \u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e \u003cli\u003e\u003cstrong\u003ePlease note that this product ships via LTL, only to commercial locations. Please contact us with questions. We only ship this to lower 48 states. \u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eSpecs\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eFlow Rate (GPM): 100\u003c\/li\u003e \u003cli\u003eFlow Rate (L\/Sec): 6.31\u003c\/li\u003e \u003cli\u003eCapacity: Lbs (MIN) 200 \/ Kg (MIN) 91\u003c\/li\u003e \u003cli\u003eCapacity (Actual - ASME A112.4.3): 1080 Lbs \/ 480 Kg\u003c\/li\u003e \u003cli\u003eSolids Capacity Lbs (Kg) estimated: 350lbs (118kg) 60 Gallons\u003c\/li\u003e \u003cli\u003eAverage Efficiency % (ASME A112.4.3): 99%\u003c\/li\u003e \u003cli\u003eOperating Temperature Capabilities (Intermittent discharge): 160° F (71°C)\u003c\/li\u003e \u003cli\u003eUnit Weight Capacity (Empty): 283 lbs (128 kgs)\u003c\/li\u003e \u003cli\u003eLiquid Capacity: 257 gal (973L)\u003c\/li\u003e \u003cli\u003eConnection size (mechanical): 4\"\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/pages\/cad-drawings\"\u003eView and download CAD Drawings and Submittal Sheets\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eCover Options\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cspan\u003eHeavy Traffic Area Covers\u003c\/span\u003e - S-Rated Traffic Access Covers (up to 20,000 lbs)\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003ePedestrian \/ Light Traffic Covers\u003c\/span\u003e - M-Rated Traffic Access Covers \u003cspan\u003e(up to 4,000 lbs)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eCast Iron Access Covers\u003c\/span\u003e - with 2 pry points and pick hole for easy removal. (Only available with hub connection model)\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/100gpm-and-150gpm-specs.jpg?v=1781750721\" alt=\"100gpm-and-150gpm-specs.jpg\" width=\"1683\" height=\"1175\"\u003e\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/approvals.jpg?v=1781750721\" alt=\"approvals.jpg\" width=\"439\" height=\"78\"\u003e\u003c\/p\u003e \u003ch3\u003eBrochures and Comparison Info \u003c\/h3\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-xl-grease-interceptor-brochure.pdf?v=1782492392\" target=\"_blank\"\u003eDrain-Net XL Grease Interceptor Brochure\u003c\/a\u003e \u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-hgi-comparison-matrix.pdf?v=1782492394\" target=\"_blank\"\u003eDrain-Net Comparison Sheet to other brands\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"\/pages\/cad-drawings\"\u003eView and download CAD Drawings and Submittal Sheets\u003c\/a\u003e\u003c\/p\u003e \u003ch3\u003eFrequently Asked Questions:\u003c\/h3\u003e \u003cp\u003e\u003cstrong\u003eDo Drain-Net XL Tanks need to be directly vented?\u003c\/strong\u003e\u003cbr\u003eThe practice of venting a grease interceptor directly is typically related to Gravity Grease Interceptors (GGI). Unless specifically mandated by local code or bylaw, with no variance allowed, a Hydromechanical Grease Interceptor (HGI) DOES NOT require the tank to be directly vented. Venting is, however, required on the downstream drain the same as most plumbing appliances; fixtures should allow effective and unrestricted discharge of effluent.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDo I need to install a clean out before or after an interceptor?\u003c\/strong\u003e\u003cbr\u003eMost plumbing codes require an upstream and downstream cleanout immediately before and after the interceptor. This is good practice and gives positive indication of which outlet is in use.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDo I have to install the Flow Control Device?\u003c\/strong\u003e\u003cbr\u003eFor an HGI, the Flow Control is ESSENTIAL to the high performance operation of the interceptor. It must be installed as indicated and without it the interceptor is no longer meeting the requirements of its appropriate approvals. This is not acceptable to the AHJ and they should be asking for the installation to be rectified before approval is granted.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow do I size a Grease Interceptor correctly?\u003c\/strong\u003e\u003cbr\u003eA grease Interceptor can be sized using two primary methods\u003cbr\u003e1. Flow Rate – When sizing by Flow Rate there are two sub sections \u003cbr\u003eFixture Capacity: Most commonly used method for Hydromechanical Grease Interceptors this looks at the maximum capacity of fixtures connected to the interceptor and the time taken to discharge that volume of wastewater through the interceptor. Units are expressed in Gallons Per Minute (GPM). \u003cbr\u003eCalculation takes 75% of maximum capacity of all fixtures and based on a 1 or 2 minute period of time taken to discharge, results in a gallons per minute flow rate. This number is rounded up to the next available size of interceptor, i.e. 16.7gpm become a 20 GPM Grease Interceptor.\u003c\/p\u003e \u003cp\u003e1. Pipe Size:\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pipe-size.png?v=1781750727\" alt=\"pipe-size.png\" width=\"631\" height=\"181\"\u003e\u003c\/p\u003e \u003cp\u003e2. Capacity\u003c\/p\u003e \u003cp\u003eBased on the volume of wastewater capacity (gallons) of the interceptor based on discharge fixture units (DFU’s) entering the interceptor\u003cbr\u003eDFU’s are identified in Uniform Plumbing Code Ch.7 based on occupancy or use.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/capacity.png?v=1781750725\" alt=\"capacity.png\" width=\"687\" height=\"171\"\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMy jurisdiction requires Effluent Sampling via a downstream access. What do I do?\u003c\/strong\u003e\u003cbr\u003eAs an HGI approved to National performance Standards, although common for GGI (Concrete, Steel) Drain-Net XL DOES NOT typically require a separate sampling location. For those jurisdictions that do require the capability to sample, Drain-Net XL incorporates a sampling port within the \u003ca href=\"\/products\/xl-sampling-well\"\u003eoutlet assembly (sold here)\u003c\/a\u003e. This is accessed by the simple removal of the air balance\/sample port cap allowing water quality samples to be taken for analysis.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow often should an interceptor be cleaned?\u003c\/strong\u003e\u003cbr\u003eCleaning of an interceptor is a case by case situation. Each facility will have many different factors impacting need for maintenance and cleaning. A licensed contractor will have the experience and equipment necessary to help establish the right schedule of maintenance for your facility. How much will it cost to maintain my Drain-Net XL installation?\u003cbr\u003eIn terms of comparison Drain-Net XL units are significantly more compact (less internal volume) than their equivalent Gravity counterparts. As pumping is typically charged by the volume of gallons removed the ongoing maintenance will be proportionally less as well. Rates will vary significantly by region and by contractor. Always use a licensed or approved contractor to maintain your interceptor.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWhat can be connected to an interceptor in respect of wastewater discharge?\u003c\/strong\u003e\u003cbr\u003eA grease interceptor UNDER NO CIRCUMSTANCES will receive sanitary wastewater discharge – i.e. that from WC flushing for example. \u003cbr\u003eWastewater discharge to a grease interceptor will be from foodservice activities only, its application being to separate non petroleum Fats Oil and Grease from waste water. \u003cbr\u003eThe requirements for appliances and fixtures that must and must not be connected to a grease interceptor is typically defined by your local plumbing codes and or jurisdictional by-laws. You should consult a licensed plumbing professional or your local city plan check.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow does a compact HGI replace the function of a 1000 gallon concrete tank?\u003c\/strong\u003e\u003cbr\u003eA Gravity Grease Interceptor (your typical concrete tank) will be sized on capacity and therefore typically a number between 750 gallons and 1500 gallons is commonly seen. This number can however be substantially higher based on local requirement or application. In most jurisdictions, a method called the 25% rule is employed as the means to indicate or mandate the cleaning frequency. The 25% is the percentage of the total working volume of the interceptor which can be occupied by a combination of Fats , Oil and Grease and Food Solids. \u003cbr\u003eFor example: A GGI tank with a capacity of 1000 gallons can only function to a point where 250 gallons (1000 X .25) of its volume is occupied by solids and grease. That equates to approximately 1090 lbs of grease. If we assumed that 100 gallons of this is the solid material, that leaves 150 gallons of grease capacity before cleaning is “required”. On average this translates to approximately 8-10 weeks on average. \u003cbr\u003eNow compare that to an XL100 HGI. Based on the independent third party testing to determine qualified performance \u0026amp; efficiency, the Drain-Net XL100 has a significantly smaller 257 gallon total capacity, but a qualified efficiency exceeding 95%. This translates to essentially the same grease capacity as the GGI, exceeding 1000 lbs of functional grease capacity.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eI heard that plastic tanks can float in high water table areas, particularly when pumped down for cleaning.\u003c\/strong\u003e \u003cbr\u003eIs this true? \u003cbr\u003eYes it is, however Drain-Net XL is specifically designed to address this challenge. If you look at XL tanks from the end you will see that the top is wider than the bottom and that there are along the sides corrugations that are closed toward the bottom of their profile. This profile is the reverse of an ice cube sitting in a freezer tray. Typically some upward force is applied around or beneath the ice cube and out it pops! Now reverse that principle to the form of the tanks – the broad base not only provides stability but also has substantial resistance to being force upward by water or freeze-thaw action. This in conjunction with the closed corrugations positively captures the tank in the excavation once backfilled. For areas of particular concern in addition an 8” concrete slab can be poured around the base to introduce further resistance. Provision is also made for the use of ground anchors or alternates that will need to be specified locally by an engineer respective of local ground conditions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCan I install more than one Drain-Net XL unit if my jurisdiction needs a minimum capacity by code?\u003c\/strong\u003e \u003cbr\u003eIn Principal, yes you can. It will be necessary you contact your plan check or review team at the authority having jurisdiction and have your engineer submit a proposal based on the information provided.\u003c\/p\u003e \u003ch3\u003eUseful Terms and Definitions\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHGI\u003c\/strong\u003e – Industry abbreviation for Hydromechanical Grease Interceptor. By definition an HGI is designed to use managed flow, air entrainment and specifically designed features to provide an enhanced level of separation efficiency, removing non petroleum FOG (Fats, Oil and Grease) from a transition flow of waste water, generated by commercial foodservice activities (Restaurants, Cafeterias, Institutional Kitchens , Sandwich Shops and Coffee houses for example). HGI’s are performance tested for efficiency of grease separation based on National Standards. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index =1\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGGI\u003c\/strong\u003e - Industry abbreviation for Gravity Grease Interceptor. By definition a GGI has a minimum of 350USG capacity and in operation 500USG to 1500USG of capacity are most common. No flow control device. Separation of FOG is based on capacity and retention time of water (minimum 30 mins to exchange volume). At this time no performance Standards are published for GGI’s. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index = 5-10+\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGRD\u003c\/strong\u003e – Industry abbreviation for Grease Removal Device. Designed firstly as an HGI, a GRD uses a heat source and a timed or sensor based skimming (or draw-off) device to remove accumulated FOG from the separation chamber into an external container for collection and disposal. These units require daily maintenance for management of food solids. \u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eOperational Cost Index = 2.5 - 5\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCost Index\u003c\/strong\u003e: A way of indicating the relative cost of different types of interceptors to each other for broad comparison purposes. This includes product purchase, installation cost and typical maintenance.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAir Entrainment\u003c\/strong\u003e: Mixing of air with Influent using a flow control device. Air and grease are attracted to each other, the air wanting to separate from water more easily than grease. Because they become mixed together the air increases the efficiency of separation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEffluent\u003c\/strong\u003e: Waste water containing little to no FOG, being discharged out of the interceptor.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInfluent\u003c\/strong\u003e: Waste water containing uncontrolled and variable levels of FOG based on the nature and practices of the foodservice operation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSeparation Chamber\u003c\/strong\u003e: Zone inside the interceptor where grease separates from water and is retained.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003ca href=\"\/collections\/wet-waste-interceptor\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/gdru-for-grease-trap-pages_55906dd1-ce2e-4a4a-9cc2-f4eab9457f6b.jpg?v=1781750726\" alt=\"gdru-for-grease-trap-pages.jpg\" width=\"1988\" height=\"516\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Pre-Plumbed_Options_69e3ac52-4d6b-4dd7-8f1f-776997450bef.jpg?v=1786834673\" alt=\"outlet options for the grease trap\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/dynamic_inlet_87797806-1fbc-4714-a229-aa5a36bbe0c2.jpg?v=1786834686\" alt=\"dynamic inclet baffle\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/flow_control_30e7c9d2-5dfd-4662-a71b-d3208cce5835.jpg?v=1786834692\" alt=\"Integrated flow control for grease interceptor\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/load_rated_covers_13ce9460-1370-48ee-9934-a69107bf1409.gif?v=1786834696\" alt=\"load rated covers for grease interceptor endura xl\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/effluent_sampling_6ca64f86-e11d-41d2-a3e6-278e28f60fb1.png?v=1786834689\" alt=\"Integrated Water Effluent Sampling\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/riser_extensions_1ab45afc-e362-48f2-9972-072b4b1c5e68.jpg?v=1786834702\" alt=\"under ground grease interceptor riser extension\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/smart_tank_design_59457060-bdb6-4edb-9835-edcc728adbc5.jpg?v=1786834705\" alt=\"grease interceptor xl design\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/100gpm_and_150gpm-specs-dn.jpg?v=1786834711\" alt=\"Hydromechanical Grease Trap150 GPM Specs\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pickup_locations_5beef30d-8e05-4207-85fc-94fd88852f20.jpg?v=1786834699\" alt=\"pickup locations\"\u003e\u003c\/p\u003e","brand":"Endura XL Grease Traps","offers":[{"title":"Traffic Rated Cover - CSA B481.0 'S' Rated","offer_id":52470398943543,"sku":"HGI-150-04","price":4798.0,"currency_code":"USD","in_stock":true},{"title":"Pedestrian \/ Light Traffic Covers - CSA B481.0 'M' Rated","offer_id":52470398976311,"sku":"HGI-150-04M","price":4798.0,"currency_code":"USD","in_stock":true},{"title":"Cast Iron Access Covers","offer_id":52470399009079,"sku":"HGI-150-04C","price":4798.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Large_Capacity_Grease_Trap_XL_150__30701.jpg?v=1781474383"},{"product_id":"endura-xl-solids-interceptor","title":"XL Solids Interceptor","description":"\u003cp\u003e\u003cstrong\u003eHard Problems Need Solid Solutions!\u003cbr\u003e\u003c\/strong\u003eThe XL Solids Interceptors are designed for the separation and retention of solid waste material as a by-product of food service establishments, breweries and many other applications.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eUp to 90% of tank volume dedicated to the storage of solid waste\u003c\/li\u003e \u003cli\u003eLightweight for easy installation\u003c\/li\u003e \u003cli\u003eMeets Miami DERM requirements for solids interceptors in specific applications\u003c\/li\u003e \u003cli\u003eFlexible installation options to adapt to your interceptor needs\u003c\/li\u003e \u003cli\u003eTraffic rated covers with Solids Interceptor identifications for easy inspection\u003c\/li\u003e \u003cli\u003eCan accommodate flow rates up to 125 GPM.\u003c\/li\u003e \u003cli\u003eSolids Capacity - Up to 232 gal\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/div\u003e \u003cdiv\u003ePlease note that this product ships via LTL, only to commercial locations. Please contact us with questions.  We only ship this to lower 48 states.  \u003ca href=\"\/pages\/contact\"\u003eContact us\u003c\/a\u003e for customer pickup locations available throughout the US.  \u003c\/div\u003e \u003cdiv\u003e \u003c\/div\u003e \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pickup_locations_5beef30d-8e05-4207-85fc-94fd88852f20.jpg?v=1786834699\" alt=\"pickup locations\" width=\"1428\" height=\"801\"\u003e\u003c\/div\u003e  \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endura XL Grease Traps","offers":[{"title":"Default Title","offer_id":52470400155959,"sku":"40100E04","price":4729.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Large_Capacity_Grease_Trap_XL_150__56676.jpg?v=1781474419"},{"product_id":"grease-interceptor-150-gpm-375-lbs","title":"Grease Trap 150 GPM - 375 LBS","description":"\u003cp\u003eThe Drain-Net Technologies' APGI Series Grease Interceptor is designed to separate grease, oils, fats, and other sediment from large Commercial and Industrial sources. Made of seamless High Density Polyethylene (HDPE), the APGI series interceptor is lightweight, cost efficient, extremely durable and corrosion free. Non skid 3\/4” poly covers with recessed handles are standard, but all units are available with steel non-skid tread plates for traffic areas. The HDPE construction is acid resistant and solids do not easily adhere to the smooth walls, making cleaning effortless.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAbove or below ground installation\u003c\/li\u003e \u003cli\u003e1\/4\" Steel Cover for pedestrian traffic\u003c\/li\u003e \u003cli\u003eBolt on Extension\u003c\/li\u003e \u003cli\u003eRecessed Lift Handles.\u003c\/li\u003e \u003cli\u003eOptional Connection Sizes 2, 3, 4, and 6 inches\u003c\/li\u003e \u003cli\u003ePVC glued connections are standard.\u003c\/li\u003e \u003cli\u003eHD Braces for above ground installation.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSpecial sizes available to fit through narrow passages or existing walkways. Special units also available to meet larger capacities, including systems that utilize series and\/or parallel interceptors. Straight through, left, and right hand models available. A lift-gate is highly recommended for delivery. All units made in the USA!\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecifications of Model DAPGI-100\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eFlow Rate: 150 GPM\u003c\/li\u003e \u003cli\u003eGrease \/ Sludge Capacity: 250 to 378 lbs\u003c\/li\u003e \u003cli\u003eApproximate Weight: 350 lbs\u003c\/li\u003e \u003cli\u003eStandard Inlet \/ Outlet: 4\"\u003c\/li\u003e \u003cli\u003eBottom of unit to center of inlet\/outlet: 25\" to 40\" (Adjustable inlet\/outlet to provide an integral extension)\u003c\/li\u003e \u003cli\u003eLiquid Holding Capacity: 125 to 186 gal\u003c\/li\u003e \u003cli\u003eDimensions: 53.5\" Length X 29.5\" Width X 45\" Height \u003c\/li\u003e \u003cli\u003eLegs or risers can be added for underground installation. Call for quote.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e*This size not recognized yet by PDI\/UPC\/IAMPMO\u003c\/p\u003e \u003cp\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-apgi-grease-trap-spec-sheet.pdf?v=1782492397\" target=\"_blank\"\u003e\u003cspan\u003e\u003cstrong\u003eClick to view and download the Spec Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e \u003ca href=\"\/collections\/wet-waste-interceptor\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/gdru-for-grease-trap-pages.jpg?v=1781750722\" alt=\"gdru-for-grease-trap-pages.jpg\" width=\"1988\" height=\"516\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/large_20capcity_20grease_20trap_20diagram4.jpg?v=1786834445\" alt=\"Large Capacity Grease Trap Grease Interceptor GPM Sizing Chart\"\u003e\u003c\/p\u003e","brand":"PolyTrap®","offers":[{"title":"Default Title","offer_id":52470400319799,"sku":"DAPGI-150","price":4800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Ashland_Large_Grease_Trap_2__84340.jpg?v=1781474430"},{"product_id":"endura-xl-fog-control-for-miami-dade-ordinances-50-and-75-gpm","title":"Endura XL FOG Control for Miami-Dade Ordinances 50 and 75 GPM","description":"\u003ch2\u003e\u003cspan\u003eMiami-Dade DERM FOG Ordinance 2.0 Solution\u003c\/span\u003e\u003c\/h2\u003e \u003cp\u003eEach Endura® Miami-Dade DERM FOG ordinance approved solution is listed to 99% efficiency as per ASME A112.14.3. This product allows designers greater flexibility in accommodating Miami-Dade’s jurisdictional requirements.  Endura® Grease Management products have been instrumental in changing the traditional practices regarding the design of grease management solutions. Thermoplastic hydromechanical alternatives to metal and concrete interceptors are being increasingly accepted Nationwide as the new standard for grease management in commercial foodservice applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e99% efficiency FOG removal\u003c\/li\u003e \u003cli\u003eHigh capacity hydromechanical GI solutions\u003c\/li\u003e \u003cli\u003eEngineered thermoplastic\u003c\/li\u003e \u003cli\u003eLightweight and easy to install\u003c\/li\u003e \u003cli\u003eComes Standard with ‘S’ Rated Traffic Covers\u003c\/li\u003e \u003cli\u003eAirtight\/Watertight cover, frame and adjustable riser system\u003c\/li\u003e \u003cli\u003e Riser Extensions available\u003c\/li\u003e \u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/desc-enduraxl-miami-dade-models.jpg?v=1787462499\" alt=\"enduraxl-miami-dade-models.jpg\" width=\"1661\" height=\"1182\"\u003e\u003c\/p\u003e \u003ch4\u003eFlow Management\u003c\/h4\u003e \u003cp\u003eEndura XL is a Hydromechanical Grease Interceptor (HGI). Unlike traditional, large capacity Gravity Grease Interceptors (GGI), our design uses more than just the natural buoyancy of fats, oils and grease (FOG) to separate them from waste water. This results in qualified efficiency based on National performance standards to ensure the most effective removal of grease.\u003c\/p\u003e \u003ch4\u003eSolids Retention Area\u003c\/h4\u003e \u003cp\u003ePassing over the ramp, any solids or debris separate by gravity into the defined solids retention area. This significantly reduces the likelihood of grease laden particles from exiting the interceptor.\u003c\/p\u003e \u003ch4\u003eOutlet Well Features\u003c\/h4\u003e \u003cp\u003eWith FOG and solids having been effectively separated, the waste water leaves the tank via our uniquely enclosed outlet well, the effluent being discharged to the downstream drain through one of three pre-plumbed tank outlets.\u003c\/p\u003e \u003cdiv\u003e \u003ch4\u003eShipping\u003c\/h4\u003e \u003c\/div\u003e \u003cdiv\u003ePlease note that this product ships via LTL, only to commercial locations. Please contact us with questions.  We only ship this to lower 48 states.  \u003ca href=\"\/pages\/contact\"\u003eContact us\u003c\/a\u003e for customer pickup locations available throughout the US.  \u003c\/div\u003e \u003cdiv\u003e \u003c\/div\u003e \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/pickup_locations.jpg?v=1786830242\" alt=\"pickup locations\" width=\"1428\" height=\"801\"\u003e\u003c\/div\u003e","brand":"Endura XL Grease Traps","offers":[{"title":"4050HEA04 - 50 GPM with Traffic Rated Cover","offer_id":52470401696055,"sku":"4050HEA04","price":3025.0,"currency_code":"USD","in_stock":true},{"title":"4050HEA04C - 50 GPM with Cast Iron Cover","offer_id":52470401728823,"sku":"4050HEA04C","price":3025.0,"currency_code":"USD","in_stock":true},{"title":"4075HEA04 - 75 GPM with Traffic Rated Cover","offer_id":52470401761591,"sku":"4075HEA04","price":5225.0,"currency_code":"USD","in_stock":true},{"title":"4075HEA04C - 75 GPM with Cast Iron Cover","offer_id":52470401794359,"sku":"4075HEA04C","price":5225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/endura_xl__69799.jpg?v=1781474481"},{"product_id":"grease-interceptor-with-500-gallons-liquid-holding-capacity","title":"Grease Interceptor with 500 Gallons Liquid Holding Capacity","description":"\u003cp\u003e\u003cspan\u003eThe GI-500 gravity grease interceptor with 500 U.S. gallons of liquid holding capacity has a limited lifetime warranty and is made in the U.S.A. out of seamless, rotationally molded High Density Polyethylene with 3\/8” uniform wall thickness. This grease interceptor is used in restaurants, kitchens, institutions, industrial facilities such as food processing and packaging plants and other types of food processing areas where fat, oil and grease (FOG) drains with the waste water. \u003c\/span\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003eInterceptor is designed for above or below ground installation\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eincludes an adjustable lid system, sample port access, internal baffle, deep seal trap covered by lid, and internal air relief by-pass\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eAlso includes a stainless steel calibrated orifice plate (internal flow control), base for support and floor level installation and 4″ no hub inlet and outlet connections. \u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eComposite lids provide a water \/ gas tight seal and have a minimum of 20,000 LB. load capacity – in accordance with the loading requirements of AASHTO H20. \u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eThe high density polyethylene material is PE 3135 from Dow 9.39 with a density of 0.939 g\/cm3.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eCan withstand a temperature of up to and including 150 degrees Fahrenheit.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eNote that the interceptor is tested and certified to the ASME A112.14.3, CSA B481 and ANSI Z1001 Standards and listed with I.A.P.M.O. For indoor\/outdoor use. \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003eContact us for optional variations and accessories such as risers, extensions, lids, sampling ports, and alternate outlets \/ connections. We also have variations of these models for other applications including: Lint, Sand, Plaster, Fish Scales, Rice, Fur, Oil\/Sediment, decontamination, and solids.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Drain-Net Technologies","offers":[{"title":"Default Title","offer_id":52470403989815,"sku":"GI-500","price":13366.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/supermax_500__95298.jpg?v=1781474569"},{"product_id":"grease-interceptor-with-750-gallons-liquid-holding-capacity","title":"Grease Interceptor with 750 Gallons Liquid Holding Capacity","description":"\u003cp\u003e\u003cspan\u003eThe GI-750 gravity grease interceptor with 750 U.S. gallons of liquid holding capacity has a limited lifetime warranty and is made in the U.S.A. out of seamless, rotationally molded High Density Polyethylene with 3\/8” uniform wall thickness. This grease interceptor is used in restaurants, kitchens, institutions, industrial facilities such as food processing and packaging plants and other types of food processing areas where fat, oil and grease (FOG) drains with the waste water. \u003c\/span\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003eInterceptor is designed for above or below ground installation\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eIncludes an adjustable lid system, sample port access, internal baffle, deep seal trap covered by lid, and internal air relief by-pass\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eAlso includes a stainless steel calibrated orifice plate (internal flow control), base for support and floor level installation and 4″ no hub inlet and outlet connections.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eComposite lids provide a water \/ gas tight seal and have a minimum of 20,000 LB. load capacity – in accordance with the loading requirements of AASHTO H20.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eThe high density polyethylene material is PE 3135 from Dow 9.39 with a density of 0.939 g\/cm3.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eCan withstand a temperature of up to and including 150 degrees Fahrenheit.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eNote that the interceptor is tested and certified to the ASME A112.14.3, CSA B481 and ANSI Z1001 Standards and listed with I.A.P.M.O. For indoor\/outdoor use. \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eContact us for optional variations and accessories such as risers, extensions, lids, sampling ports, and alternate outlets \/ connections. We also have variations of these models for other applications including: Lint, Sand, Plaster, Fish Scales, Rice, Fur, Oil\/Sediment, decontamination, and solids.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Drain-Net Technologies","offers":[{"title":"Default Title","offer_id":52470404022583,"sku":"GI-750","price":19546.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/7500__54708.png?v=1781474571"},{"product_id":"grease-interceptor-with-1000-gallons-liquid-holding-capacity","title":"Grease Interceptor with 1000 Gallons Liquid Holding Capacity","description":"\u003cp\u003e\u003cspan\u003eThe GI-1000 gravity grease interceptor with 1000 U.S. gallons of liquid holding capacity has a limited lifetime warranty and is made in the U.S.A. out of seamless, rotationally molded High Density Polyethylene with 3\/8” uniform wall thickness. This grease interceptor is used in restaurants, kitchens, institutions, industrial facilities such as food processing and packaging plants and other types of food processing areas where fat, oil and grease (FOG) drains with the waste water. \u003c\/span\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003eInterceptor is designed for above or below ground installation\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eIncludes an adjustable lid system, sample port access, internal baffle, deep seal trap covered by lid, and internal air relief by-pass\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eAlso includes a stainless steel calibrated orifice plate (internal flow control), base for support and floor level installation and 4″ no hub inlet and outlet connections.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eComposite lids provide a water \/ gas tight seal and have a minimum of 20,000 LB. load capacity – in accordance with the loading requirements of AASHTO H20.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eThe high density polyethylene material is PE 3135 from Dow 9.39 with a density of 0.939 g\/cm3.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eCan withstand a temperature of up to and including 150 degrees Fahrenheit.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eNote that the interceptor is tested and certified to the ASME A112.14.3, CSA B481 and ANSI Z1001 Standards and listed with I.A.P.M.O. For indoor\/outdoor use. \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eContact us for optional variations and accessories such as risers, extensions, lids, sampling ports, and alternate outlets \/ connections. We also have variations of these models for other applications including: Lint, Sand, Plaster, Fish Scales, Rice, Fur, Oil\/Sediment, decontamination, and solids.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Drain-Net Technologies","offers":[{"title":"Default Title","offer_id":52470404055351,"sku":"GI-1000","price":22192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/GI1000__07231.jpg?v=1781474572"},{"product_id":"grease-interceptor-with-1500-gallons-liquid-holding-capacity","title":"Grease Interceptor with 1500 Gallons Liquid Holding Capacity","description":"\u003cp\u003e\u003cspan\u003eThe GI-1500 gravity grease interceptor with 1500 U.S. gallons of liquid holding capacity has a limited lifetime warranty and is made in the U.S.A. out of seamless, rotationally molded High Density Polyethylene with 3\/8” uniform wall thickness. This grease interceptor is used in restaurants, kitchens, institutions, industrial facilities such as food processing and packaging plants and other types of food processing areas where fat, oil and grease (FOG) drains with the waste water. \u003c\/span\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003eInterceptor is designed for above or below ground installation\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eIncludes an adjustable lid system, sample port access, internal baffle, deep seal trap covered by lid, and internal air relief by-pass\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eAlso includes a stainless steel calibrated orifice plate (internal flow control), base for support and floor level installation and 4″ no hub inlet and outlet connections.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eComposite lids provide a water \/ gas tight seal and have a minimum of 20,000 LB. load capacity – in accordance with the loading requirements of AASHTO H20.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eThe high density polyethylene material is PE 3135 from Dow 9.39 with a density of 0.939 g\/cm3.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eCan withstand a temperature of up to and including 150 degrees Fahrenheit.\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eNote that the interceptor is tested and certified to the ASME A112.14.3, CSA B481 and ANSI Z1001 Standards and listed with I.A.P.M.O. For indoor\/outdoor use. \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eContact us for optional variations and accessories such as risers, extensions, lids, sampling ports, and alternate outlets \/ connections. We also have variations of these models for other applications including: Lint, Sand, Plaster, Fish Scales, Rice, Fur, Oil\/Sediment, decontamination, and solids.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Drain-Net Technologies","offers":[{"title":"Default Title","offer_id":52470404088119,"sku":"GI-1500","price":28542.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/GI1500__33553.jpg?v=1781474574"},{"product_id":"75-gpm-hydro-mechanical-rotational-molded-grease-interceptor","title":"75 GPM Hydro Mechanical Rotational Molded Grease Interceptor","description":"\u003cp\u003e\u003cspan\u003e75 HDPE rotational molded grease interceptor with flow rating of 75 GPM and liquid holding capacity of 140 gal. Steel encased composite lid provides a water\/gas tight seal and has a minimum of 20000 lb load capacity. Unit shall include: 3\/8 in uniform wall thickness, deep seal trap covered by lid, internal air relief by-pass, adjustable lid system, stainless steel calibrated orifice plate (internal flow control), sample port access and 4 in no hub inlet and outlet connections. Steel encased composite lid provides a water \/ gas tight seal and has a minimum of 20000 lb load capacity. The lid is designed in accordance with the loading requirements of AASHTO H20. Interceptor shall be tested and certified to the PDI Standard PDI-G101, CSA B481, ASME A112.14.3 and listed with IAPMO. This grease interceptor is also in compliance with International Plumbing Code (IPC)\/ICC by IAPMO.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003eUsed in restaurants, kitchens, institutional and industrial facilities such as food processing and packaging plants and other types of food processing areas where fat, oil and grease (FOG) drains with the waste water. Typically installed either on or into the floor. Narrow width permits access through doorways and down stairwells. High Density Polyethylene construction ensures a lightweight installation process (two people can move and install it). Regular maintenance is required to keep the interceptor functioning. Can withstand a temperature of up to and including 150O Fahrenheit.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/b-specs.jpg?v=1781750721\" alt=\"b-specs.jpg\" width=\"1976\" height=\"990\"\u003e \u003c\/p\u003e \u003ch2\u003eFeatures and Benefits\u003c\/h2\u003e \u003ch3\u003eExternal Vented Flow Control Fitting\u003c\/h3\u003e \u003cp\u003eAll of Drain-Tech's PDI approved grease interceptors are supplied with an external, vented flow control fitting. Studies have proven that the use of an external, vented flow control fitting results in more effective grease interception because of the air introduced into the drain line through the vent in the top of the flow control fitting. As this air enters the interceptor, grease coats the resulting air bubbles and increases the efficiency of the grease rising to the surface.\u003c\/p\u003e \u003ch3\u003eSample Port Access\u003c\/h3\u003e \u003cp\u003eSample port access is provided standard in our interceptors. Simply remove the lid to gain access to the top opening of the internal inlet and outlet piping. A sample of the water discharging from the interceptor can be taken from the top opening of the outlet piping (deep seal trap).\u003c\/p\u003e \u003ch3\u003eH-20 Load Rated Lid\u003c\/h3\u003e \u003cp\u003eStandard, 20,000 Lb. AASHTO H-20 load rated steel encased composite, gasketed lids and collar are standard to withstand heavy loads\u003c\/p\u003e \u003ch3\u003eStructural Integrity\u003c\/h3\u003e \u003cp\u003eRibbed body design provides extra structural integrity for in ground installations. The body is manufactured in the USA out of seamless, rotationally molded High Density Polyethylene with a 3\/8” uniform wall thickness. The body is strong but lightweight, allowing it to be installed without the need of a backhoe or crane. The H.D.P.E. material will not crack, chip or bulge under extreme impact, sunlight and \/ or temperature changes. H.D.P.E. is a much better material for interceptors than fiberglass because H.D.P.E. has resistance to a greater number of chemicals than fiberglass. Fiberglass is also hard and stiff and is subject to cracking. A rotationally molded H.D.P.E. interceptor is simply tougher and has much greater impact resistance vs. fiberglass. Fiberglass interceptors also have a negative environmental impact because they are made with VOCs - (Volatile Organic Compounds). Facilities that produce fiberglass interceptor shave a negative impact on the environment because of VOCs they put into the air. Rotationally molded H.D.P.E. interceptors have NO environmental impact. Can withstand a temperature of up to and including 150O Fahrenheit.\u003c\/p\u003e \u003ch3\u003eNarrow Width\u003c\/h3\u003e \u003cp\u003eThe 33 ½” width allows the interceptor to fit through doorways and down stairwells. Two people can carry and install the interceptor.\u003c\/p\u003e \u003ch3\u003eRiser Extensions\u003c\/h3\u003e \u003cp\u003eWith the patented extension system, the contractor has the option to purchase an extension from Drain-Tech or to buy a length of ADS pipe from their local waterworks wholesaler in order to complete the installation immediately. This also means that the cost of our extension (when ordered from a local waterworks wholesaler will be significantly less expensive that buying the same height extension system from others). In addition, extensions from others are only available from that specific manufacturer – resulting in delays and time for production and shipment to the contractor. Flexible extensions make for easier installation where grade may be unlevel.\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eExtra Rough-in Dimension\u003c\/span\u003e\u003c\/h2\u003e \u003cp\u003eThe standard rough-in dimension (“C” dimension – from the middle of the inlet \/ outlet to the top of the lid) is 24½” and can be field adjusted by the contractor down to 15 ½” on the B-750 and to 16\" on the B-1150. The 24½” rough-in dimension provided is almost double that of others – making it less likely to buy expensive extensions.\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eForklift Access\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eForklift access points are provided in the bottom of the interceptors to allow for easy handling.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eGrip Points for Anchor Kit\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eTwo grip points are provided on each side of the interceptor for easy handling. These grip points also serve as securing areas for our high water anchor kit which allows the contractor to secure the interceptor to the ground before concrete is poured around the unit (Suffix –AK).\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOptions and Accessories\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003e40 years of experience with grease interceptors provides us with a superior knowledge of options and accessories often required with grease interceptors. We can expertly provide any of the following options: dosing pump, anchor kit, remote pump out, enzyme port, high level alarm, multiple inlet and outlet ports, sediment bucket and threaded connections.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eMultiple Inlet\/Outlet Options\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eManufactured with two flat spaces on each side for two optional side inlets or outlets on both sides of the interceptor. This allows for straight through or side inlet\/outlet pipe connections. (Specify required suffix for desired optional inlet\/outlet).\u003c\/span\u003e \u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eLifetime Warranty\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eMade in the USA, manufacturer offers a limited lifetime warranty. Meets the requirements of the Buy American Act.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eTested and certified to the PDI G-101, ASME A112.14.3 and CSA B481 Standards and listed with I.A.P.M.O. Also in compliance with International Plumbing Code (I.P.C.) \/ I.C.C. by I.A.P.M.O.\u003c\/span\u003e\u003c\/p\u003e","brand":"Drain-Net Technologies","offers":[{"title":"Default Title","offer_id":52470404120887,"sku":"B-750","price":3594.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/B-750__70352.jpg?v=1781474578"},{"product_id":"50-gpm-hydro-mechanical-rotational-molded-grease-interceptor","title":"50 GPM Hydro Mechanical Rotational Molded Grease Interceptor","description":"\u003cp\u003e\u003cspan\u003eHDPE rotational molded grease interceptor with flow rating of 05 GPM and liquid holding capacity of 55 gal. Steel encased composite lid provides a water\/gas tight seal and has a minimum of 20000 lb load capacity. Unit shall include: 3\/8 in uniform wall thickness, deep seal trap covered by lid, internal air relief by-pass, adjustable lid system, stainless steel calibrated orifice plate (internal flow control), sample port access and 4 in no hub inlet and outlet connections. Steel encased composite lid provides a water \/ gas tight seal and has a minimum of 20000 lb load capacity. The lid is designed in accordance with the loading requirements of AASHTO H20. Interceptor shall be tested and certified to the PDI Standard PDI-G101, CSA B481, ASME A112.14.3 and listed with IAPMO. This grease interceptor is also in compliance with International Plumbing Code (IPC)\/ICC by IAPMO.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003eUsed in restaurants, kitchens, institutional and industrial facilities such as food processing and packaging plants and other types of food processing areas where fat, oil and grease (FOG) drains with the waste water. Typically installed either on or into the floor. Narrow width permits access through doorways and down stairwells. High Density Polyethylene construction ensures a lightweight installation process (two people can move and install it). Regular maintenance is required to keep the interceptor functioning. Can withstand a temperature of up to and including 150O Fahrenheit.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/b-specs.jpg?v=1781750721\" alt=\"b-specs.jpg\" width=\"1976\" height=\"990\"\u003e \u003c\/p\u003e \u003ch2\u003eFeatures and Benefits\u003c\/h2\u003e \u003ch3\u003eExternal Vented Flow Control Fitting\u003c\/h3\u003e \u003cp\u003eAll of Drain-Tech's PDI approved grease interceptors are supplied with an external, vented flow control fitting. Studies have proven that the use of an external, vented flow control fitting results in more effective grease interception because of the air introduced into the drain line through the vent in the top of the flow control fitting. As this air enters the interceptor, grease coats the resulting air bubbles and increases the efficiency of the grease rising to the surface.\u003c\/p\u003e \u003ch3\u003eSample Port Access\u003c\/h3\u003e \u003cp\u003eSample port access is provided standard in our interceptors. Simply remove the lid to gain access to the top opening of the internal inlet and outlet piping. A sample of the water discharging from the interceptor can be taken from the top opening of the outlet piping (deep seal trap).\u003c\/p\u003e \u003ch3\u003eH-20 Load Rated Lid\u003c\/h3\u003e \u003cp\u003eStandard, 20,000 Lb. AASHTO H-20 load rated steel encased composite, gasketed lids and collar are standard to withstand heavy loads\u003c\/p\u003e \u003ch3\u003eStructural Integrity\u003c\/h3\u003e \u003cp\u003eRibbed body design provides extra structural integrity for in ground installations. The body is manufactured in the USA out of seamless, rotationally molded High Density Polyethylene with a 3\/8” uniform wall thickness. The body is strong but lightweight, allowing it to be installed without the need of a backhoe or crane. The H.D.P.E. material will not crack, chip or bulge under extreme impact, sunlight and \/ or temperature changes. H.D.P.E. is a much better material for interceptors than fiberglass because H.D.P.E. has resistance to a greater number of chemicals than fiberglass. Fiberglass is also hard and stiff and is subject to cracking. A rotationally molded H.D.P.E. interceptor is simply tougher and has much greater impact resistance vs. fiberglass. Fiberglass interceptors also have a negative environmental impact because they are made with VOCs - (Volatile Organic Compounds). Facilities that produce fiberglass interceptor shave a negative impact on the environment because of VOCs they put into the air. Rotationally molded H.D.P.E. interceptors have NO environmental impact. Can withstand a temperature of up to and including 150O Fahrenheit.\u003c\/p\u003e \u003ch3\u003eNarrow Width\u003c\/h3\u003e \u003cp\u003eThe 33 ½” width allows the interceptor to fit through doorways and down stairwells. Two people can carry and install the interceptor.\u003c\/p\u003e \u003ch3\u003eRiser Extensions\u003c\/h3\u003e \u003cp\u003eWith the patented extension system, the contractor has the option to purchase an extension from Drain-Tech or to buy a length of ADS pipe from their local waterworks wholesaler in order to complete the installation immediately. This also means that the cost of our extension (when ordered from a local waterworks wholesaler will be significantly less expensive that buying the same height extension system from others). In addition, extensions from others are only available from that specific manufacturer – resulting in delays and time for production and shipment to the contractor. Flexible extensions make for easier installation where grade may be unlevel.\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eExtra Rough-in Dimension\u003c\/span\u003e\u003c\/h2\u003e \u003cp\u003eThe standard rough-in dimension (“C” dimension – from the middle of the inlet \/ outlet to the top of the lid) is 24½” and can be field adjusted by the contractor down to 15 ½” on the BIG-750 and to 16\" on the BIG-1150. The 24½” rough-in dimension provided is almost double that of others – making it less likely to buy expensive extensions.\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eForklift Access\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eForklift access points are provided in the bottom of the interceptors to allow for easy handling.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eGrip Points for Anchor Kit\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eTwo grip points are provided on each side of the interceptor for easy handling. These grip points also serve as securing areas for our high water anchor kit which allows the contractor to secure the interceptor to the ground before concrete is poured around the unit (Suffix –AK).\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOptions and Accessories\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003e40 years of experience with grease interceptors provides us with a superior knowledge of options and accessories often required with grease interceptors. We can expertly provide any of the following options: dosing pump, anchor kit, remote pump out, enzyme port, high level alarm, multiple inlet and outlet ports, sediment bucket and threaded connections.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eMultiple Inlet\/Outlet Options\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eManufactured with two flat spaces on each side for two optional side inlets or outlets on both sides of the interceptor. This allows for straight through or side inlet\/outlet pipe connections. (Specify required suffix for desired optional inlet\/outlet).\u003c\/span\u003e \u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eLifetime Warranty\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eMade in the USA, manufacturer offers a limited lifetime warranty. Meets the requirements of the Buy American Act.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eTested and certified to the PDI G-101, ASME A112.14.3 and CSA B481 Standards and listed with I.A.P.M.O. Also in compliance with International Plumbing Code (I.P.C.) \/ I.C.C. by I.A.P.M.O.\u003c\/span\u003e\u003c\/p\u003e","brand":"Drain-Net Technologies","offers":[{"title":"Default Title","offer_id":52470404219191,"sku":"B-500","price":2646.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/B-500__00900.jpg?v=1781474582"},{"product_id":"100-gpm-hydro-mechanical-rotational-molded-grease-interceptor","title":"100 GPM Hydro Mechanical Rotational Molded Grease Interceptor","description":"\u003cp\u003e\u003cspan\u003eHDPE rotational molded grease interceptor with flow rating of 100 GPM and liquid holding capacity of 300 gal. Steel encased composite lid provides a water\/gas tight seal and has a minimum of 20,000 lbs load capacity. Unit shall include: 3\/8 in uniform wall thickness, deep seal trap covered by lid, internal air relief by-pass, adjustable lid system, stainless steel calibrated orifice plate (internal flow control), sample port access and 4 in no hub inlet and outlet connections. Steel encased composite lid provides a water \/ gas tight seal and has a minimum of 20000 lb load capacity. The lid is designed in accordance with the loading requirements of AASHTO H20. Interceptor shall be tested and certified to the PDI Standard PDI-G101, CSA B481, ASME A112.14.3 and listed with IAPMO. This grease interceptor is also in compliance with International Plumbing Code (IPC)\/ICC by IAPMO.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003eUsed in restaurants, kitchens, institutional and industrial facilities such as food processing and packaging plants and other types of food processing areas where fat, oil and grease (FOG) drains with the waste water. Typically installed either on or into the floor. Narrow width permits access through doorways and down stairwells. High Density Polyethylene construction ensures a lightweight installation process (two people can move and install it). Regular maintenance is required to keep the interceptor functioning. Can withstand a temperature of up to and including 150O Fahrenheit.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/b-specs.jpg?v=1781750721\" alt=\"b-specs.jpg\" width=\"1976\" height=\"990\"\u003e \u003c\/p\u003e \u003ch2\u003eFeatures and Benefits\u003c\/h2\u003e \u003ch3\u003eExternal Vented Flow Control Fitting\u003c\/h3\u003e \u003cp\u003eAll of Drain-Tech's PDI approved grease interceptors are supplied with an external, vented flow control fitting. Studies have proven that the use of an external, vented flow control fitting results in more effective grease interception because of the air introduced into the drain line through the vent in the top of the flow control fitting. As this air enters the interceptor, grease coats the resulting air bubbles and increases the efficiency of the grease rising to the surface.\u003c\/p\u003e \u003ch3\u003eSample Port Access\u003c\/h3\u003e \u003cp\u003eSample port access is provided standard in our interceptors. Simply remove the lid to gain access to the top opening of the internal inlet and outlet piping. A sample of the water discharging from the interceptor can be taken from the top opening of the outlet piping (deep seal trap).\u003c\/p\u003e \u003ch3\u003eH-20 Load Rated Lid\u003c\/h3\u003e \u003cp\u003eStandard, 20,000 Lb. AASHTO H-20 load rated steel encased composite, gasketed lids and collar are standard to withstand heavy loads\u003c\/p\u003e \u003ch3\u003eStructural Integrity\u003c\/h3\u003e \u003cp\u003eRibbed body design provides extra structural integrity for in ground installations. The body is manufactured in the USA out of seamless, rotationally molded High Density Polyethylene with a 3\/8” uniform wall thickness. The body is strong but lightweight, allowing it to be installed without the need of a backhoe or crane. The H.D.P.E. material will not crack, chip or bulge under extreme impact, sunlight and \/ or temperature changes. H.D.P.E. is a much better material for interceptors than fiberglass because H.D.P.E. has resistance to a greater number of chemicals than fiberglass. Fiberglass is also hard and stiff and is subject to cracking. A rotationally molded H.D.P.E. interceptor is simply tougher and has much greater impact resistance vs. fiberglass. Fiberglass interceptors also have a negative environmental impact because they are made with VOCs - (Volatile Organic Compounds). Facilities that produce fiberglass interceptor shave a negative impact on the environment because of VOCs they put into the air. Rotationally molded H.D.P.E. interceptors have NO environmental impact. Can withstand a temperature of up to and including 150O Fahrenheit.\u003c\/p\u003e \u003ch3\u003eNarrow Width\u003c\/h3\u003e \u003cp\u003eThe 33 ½” width allows the interceptor to fit through doorways and down stairwells. Two people can carry and install the interceptor.\u003c\/p\u003e \u003ch3\u003eRiser Extensions\u003c\/h3\u003e \u003cp\u003eWith the patented extension system, the contractor has the option to purchase an extension from Drain-Tech or to buy a length of ADS pipe from their local waterworks wholesaler in order to complete the installation immediately. This also means that the cost of our extension (when ordered from a local waterworks wholesaler will be significantly less expensive that buying the same height extension system from others). In addition, extensions from others are only available from that specific manufacturer – resulting in delays and time for production and shipment to the contractor. Flexible extensions make for easier installation where grade may be unlevel.\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eExtra Rough-in Dimension\u003c\/span\u003e\u003c\/h2\u003e \u003cp\u003eThe standard rough-in dimension (“C” dimension – from the middle of the inlet \/ outlet to the top of the lid) is 24½” and can be field adjusted by the contractor down to 15 ½” on the B-750 and to 16\" on the B-1150. The 24½” rough-in dimension provided is almost double that of others – making it less likely to buy expensive extensions.\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eForklift Access\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eForklift access points are provided in the bottom of the interceptors to allow for easy handling.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eGrip Points for Anchor Kit\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eTwo grip points are provided on each side of the interceptor for easy handling. These grip points also serve as securing areas for our high water anchor kit which allows the contractor to secure the interceptor to the ground before concrete is poured around the unit (Suffix –AK).\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOptions and Accessories\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003e40 years of experience with grease interceptors provides us with a superior knowledge of options and accessories often required with grease interceptors. We can expertly provide any of the following options: dosing pump, anchor kit, remote pump out, enzyme port, high level alarm, multiple inlet and outlet ports, sediment bucket and threaded connections.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eMultiple Inlet\/Outlet Options\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eManufactured with two flat spaces on each side for two optional side inlets or outlets on both sides of the interceptor. This allows for straight through or side inlet\/outlet pipe connections. (Specify required suffix for desired optional inlet\/outlet).\u003c\/span\u003e \u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eLifetime Warranty\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eMade in the USA, manufacturer offers a limited lifetime warranty. Meets the requirements of the Buy American Act.\u003c\/span\u003e\u003c\/p\u003e \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/h2\u003e \u003cp dir=\"ltr\"\u003e\u003cspan\u003eTested and certified to the PDI G-101, ASME A112.14.3 and CSA B481 Standards and listed with I.A.P.M.O. Also in compliance with International Plumbing Code (I.P.C.) \/ I.C.C. by I.A.P.M.O.\u003c\/span\u003e\u003c\/p\u003e","brand":"Drain-Net Technologies","offers":[{"title":"Default Title","offer_id":52470404284727,"sku":"B-1150","price":6429.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/B-1150-grease-interceptor__87723.jpg?v=1781474585"},{"product_id":"grease-interceptor-250-gpm-625-lbs","title":"Grease Trap 250 GPM - 625 LBS","description":"\u003cp\u003e\u003cstrong\u003e250 GPM Grease Interceptor with 625 LB grease capacity.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Drain-Net APGI Series Grease Interceptor is designed to separate grease, oils, fats, and other sediment from large Commercial and Industrial sources. Made of seamless High Density Polyethylene (HDPE), the APGI series interceptor is lightweight, cost efficient, extremely durable and corrosion free.  Non skid 3\/4” poly covers with recessed handles are standard, but all units are available with steel non-skid tread plates for traffic areas.  The HDPE construction is acid resistant and solids do not easily adhere to the smooth walls, making cleaning effortless.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Above or below ground installation\u003cbr\u003e• 1\/4\" Steel Cover for pedestrian traffic\u003cbr\u003e• Bolt on Extension\u003cbr\u003e• Recessed Lift Handles.\u003cbr\u003e• Standard Inlet: 4\"\u003cbr\u003e• Optional Connection Sizes 2, 3, 5, and 6 inches\u003cbr\u003e• PVC glued connections are standard.\u003cbr\u003e• HD Braces for above ground installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSpecial sizes available to fit through narrow passages or existing walkways. Special units also available to meet larger capacities, including systems that utilize series and\/or parallel interceptors. Straight through, left, and right hand models available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications of Model DAPGI-250\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFlow Rate: 250 GPM\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGrease \/ Sludge Capacity: 625 lbs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApproximate Weight: 475 lbs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eStandard Inlet \/ Outlet: 4\" \u003c\/span\u003e\u003cspan\u003e(optional connection sizes 2 through 6 inches)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBottom of unit to center of inlet\/outlet: 45\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLiquid Holding Capacity: 405 gal\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDimensions: 77\" Length X 41\" Width X 49.5\" Height\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLegs or risers can be added for underground installation. Call for quote.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*This size not recognized yet by PDI\/UPC\/IAMPMO\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/large_capcity_grease_trap_diagram4_1024x1024.jpg?v=1786837587\" alt=\"Large Capacity Grease Trap Grease Interceptor GPM Sizing Chart\" style=\"margin-top: 2px; float: none;\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PolyTrap®","offers":[{"title":"Default Title","offer_id":52470411264311,"sku":"DAPGI-250","price":7800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Ashland_Large_Grease_Trap_2__44977.jpg?v=1781474749"},{"product_id":"grease-interceptor-350-gpm-850-lbs","title":"Grease Trap 350 GPM - 850 LBS","description":"\u003cp\u003eThe Drain-Net Technologies APGI Series Grease Interceptor is designed to separate grease, oils, fats, and other sediment from large Commercial and Industrial sources. Made of seamless High Density Polyethylene (HDPE), the APGI series interceptor is lightweight, cost efficient, extremely durable and corrosion free. Non skid 3\/4” poly covers with recessed handles are standard, but all units are available with steel non-skid tread plates for traffic areas. The HDPE construction is acid resistant and solids do not easily adhere to the smooth walls, making cleaning effortless.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAbove or below ground installation\u003c\/li\u003e \u003cli\u003e1\/4\" Steel Cover for pedestrian traffic\u003c\/li\u003e \u003cli\u003eBolt on Extension\u003c\/li\u003e \u003cli\u003eRecessed Lift Handles.\u003c\/li\u003e \u003cli\u003eStandard connection size: 6\"\u003c\/li\u003e \u003cli\u003eOptional Connection Sizes 2, 3, 4 and 6 inches\u003c\/li\u003e \u003cli\u003ePVC glued connections are standard.\u003c\/li\u003e \u003cli\u003eHD Braces for above ground installation.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSpecial sizes available to fit through narrow passages or existing walkways. Special units also available to meet larger capacities, including systems that utilize series and\/or parallel interceptors. Straight through, left, and right hand models available. A lift-gate is highly recommended for delivery. All units made in the USA!\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecifications of Model DAPGI-350\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eFlow Rate: 350 GPM\u003c\/li\u003e \u003cli\u003eGrease \/ Sludge Capacity: 850 lbs\u003c\/li\u003e \u003cli\u003eApproximate Weight: 650 lbs\u003c\/li\u003e \u003cli\u003eStandard Inlet \/ Outlet: 6\"\u003c\/li\u003e \u003cli\u003eBottom of unit to center of inlet\/outlet: 57.5\"\u003c\/li\u003e \u003cli\u003eLiquid Holding Capacity: 560 gal\u003c\/li\u003e \u003cli\u003eDimensions: 77\" Length X 41\" Width X 61\" Height \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e*This size not recognized yet by PDI\/UPC\/IAMPMO\u003c\/p\u003e \u003cp\u003e\u003cspan\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/drain-net-apgi-grease-trap-spec-sheet.pdf?v=1782492397\" target=\"_blank\"\u003e\u003cspan\u003e\u003cstrong\u003eClick to view and download the Spec Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"\/collections\/wet-waste-interceptor\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/gdru-for-grease-trap-pages.jpg?v=1781750722\" alt=\"gdru-for-grease-trap-pages.jpg\" width=\"1988\" height=\"516\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/large_20capcity_20grease_20trap_20diagram4.jpg?v=1786834445\" alt=\"Large Capacity Grease Trap Grease Interceptor GPM Sizing Chart\"\u003e\u003c\/p\u003e","brand":"PolyTrap®","offers":[{"title":"Default Title","offer_id":52470411329847,"sku":"DAPGI-350","price":8800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/files\/Ashland_Large_Grease_Trap_2__18437.jpg?v=1781474751"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/5686\/5335\/collections\/supermax_500__95298.jpg?v=1787003996","url":"https:\/\/www.drain-net.com\/collections\/large-capacity-grease-traps.oembed","provider":"Drain-Net","version":"1.0","type":"link"}